Zurück
Vor

HI83730-02 Photometer for the Determination of Peroxide Value in Olive Oils

Manufacturer: HANNA Instruments Inc.

Order number: HI83730-02

 

Delivery time approx. 2 to 4 weeks

R 18,330.00 *
 
 
 
 
 

Product information "HI83730-02 Photometer for the Determination of Peroxide Value in Olive Oils"

 

 

The HI 83730 is an instrument that benefits from HANNA’s years of experience as a manufacturer of analytical instruments. It has an advanced optical system based on a special tungsten lamp and a narrow band interference filter that allows the most accurate and repeatable readings. All instruments are factory calibrated.

The auto-diagnostic feature of this meter ensures optimal measurement conditions for highly precise readings. The light level is automatically adjusted each time a zero-measurement is made, and the lamp is temperature controlled to avoid overheating.

Significance and Use

Peroxides are the primary products of oil oxidation. Their identification gives useful information about oil conservation and rancidity. HI 83730 allows a fast and simple analysis of peroxides in oil in accordance with the EC 2568/91 method.

 

For reagents, please see: HI 83730-20 

 

 

Order Information:
HI 83730-01 (115V) and HI 83730-02 (230V) are supplied with 1 mL syringes (4), scissors, vial cleaning cloth, batteries, AC adapter, instructions and a rigid carrying case.

?SPECIFICATIONS:

Range   0.0 to 25.0 meq O2kg
Resolution   0.5 meq O2/kg
Accuracy @ 25°C   ±0.5 meq O2/kg
Light Source   tungsten lamp
Light Detector   silicon photocell with narrow band interference filter @ 466 nm
Environment   0 to 50°C (32 to 122ºF); RH max 95% non-condensing
Power Supply   1.5V AA batteries (4) / 12 VDC adapter
Auto-off   after 15 minutes of non-use
Dimensions   224 x 87 x 77 mm (8.8 x 3.4 x 3”)
Weight   512 g (18 oz.)
Method   adaptation of EC 2568/91 method and following amendments
Product Manuals

  Manual: Download

Solutions
HI 93703-50 Cuvette Cleaning Solution
Accessories
HI 740216 Test Tube Cooling Rack
HI 740142P Graduated Syringe Set (10), 1 mL
HI 731318 Cuvette Cleaning Cloth
HI 710005 Power Adapter, 115 Vac to 12 VDC, US Plug
HI 710006 Power Adapter, 230 Vac to 12 VDC, European Plug
Reagents & Standards
HI 83730-20 Peroxide in Olive Oil Reagents
 

Onward links to "HI83730-02 Photometer for the Determination of Peroxide Value in Olive Oils"

Further products by HANNA Instruments Inc.
 

Customer evaluation "HI83730-02 Photometer for the Determination of Peroxide Value in Olive Oils"

 

Write an evaluation

 
 
 
 
 
 
 

The fields marked with * are required.