Hanna Instruments Worldwide
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +27 (0) 11 615-6076
Hanna Instruments Worldwide
Customer Support: +1 (800) 426-6287

Chloride Combination Ion-Selective Electrode (ISE) - HI4107

R28,779.00 Excl VAT

Availability on Request

The HI4107 is a solid state, combination ion selective electrode (ISE) for the determination of chloride (Cl) in solution. The silver chloride sensing pellet produces a potential change due to the chloride ion exchange between the inorganic pellet membrane and the sample. The internal sensing elements are housed within a durable polyetherimide (PEI) body.

The HI4107 is ideal for a variety of applications in food and beverages, agriculture, and water treatment.

  • Solid state sensor
  • Skirted cone geometry
  • Detection from 1.8 to 35, 500 mg/L Cl

Description

The HI4107 chloride ion-selective electrode is a complete potentiometric cell that contains a silver/silver chloride (Ag/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver chloride sensing membrane.

Hanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.

For the HI4107 to measure chloride accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free chloride ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4107 chloride solid state ISE can measure from 50µM (1.8 mg/L) to 1M (35, 500 mg/L).

Conversion Table for Cl

Multiply

moles/L (M) to ppm (mg/L)

3.500 x 104

ppm (mg/L) to M (moles/L)

2.857 x 10-5

Features at-a-glance

Fixed Sensing Modules – Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.

Durable PEI Body – The probe body is composed of durable polyetherimide (PEI) plastic.

BNC Connection – The HI4107 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.

Theory of Operation

A solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.

Additional information

Weight 0.45 kg
Parameter

Chloride

Temperature Range

0 to 80 °C

Specifications

SKU HI4107
Name Chloride Combination Ion-Selective Electrode (ISE) – HI4107
Description combination
Measurement Range chloride (Cl) 1.0M to 5 x 10-5M, 35,500 to 1.8 mg/L (ppm)
Temperature Range 0 to 80 ?C
Body Material PEI
Optimum pH Range pH 2 to 11
Body Length/Overall Length 120 mm
Outer Diameter 12 mm
Cable coaxial; 1 m (3.3’)
Connector Type BNC
Notes Approximate Slope -56 mV

Manuals

Chloride Combination Ion-Selective Electrode (ISE) – HI4107