Hanna Instruments Worldwide
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +27 (0) 11 615-6076
Hanna Instruments Worldwide
Customer Support: +1 (800) 426-6287

HI70671L Cleaning & Disinfection Solution for Algae, Fungi and Bacteria (500 mL)

R1,131.00 Excl VAT

Availability on Request

The HI70671L is an effective, acidic effective cleaning solution that is specially formulated for use in applications were a pH electrode can be coated with algae, fungi and bacteria. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna’s cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement and stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and prevent any clogging of the junction.

Hanna’s line of cleaning solutions have been specially formulated to have an expiration of 5 years from the date of manufacture for an unopened bottle.

  • Specially formulated cleaning solution to remove bacterial products from a pH electrode
  • Air tight bottle with tamper-proof seal to ensure quality
  • Expiration date and lot number clearly marked on the bottle

Description

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.

The Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI70671L is a cleaning solution made for industrial applications where electrodes can become coated with algae, fungi or bacteria.

Air tight bottle with tamper-proof seal

  • Ensures quality and freshness of solution

Each bottle marked with lot number and expiration date

  • Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.

Additional information

Weight 0.55 kg
Parameter

pH

Specifications

SKU HI70671L
Name HI70671L Cleaning & Disinfection Solution for Algae, Fungi and Bacteria (500 mL)
Description cleaning and disinfection solution for algae, fungi and bacteria (industrial processes)
Certificate of Analysis no
Package bottle
Quantity 1
Size 500 mL

Manuals

HI70671L Cleaning & Disinfection Solution for Algae, Fungi and Bacteria (500 mL)