Fluoride Low-Range Checker® HC - HI729

R2,111.00 Excl VAT

Availability on Request

With our low-range fluoride colorimeter you achieve more precise technology than your standard chemical test kit. You won’t have to struggle to determine colors visually, our handheld colorimeter eliminates the hassle of matching to a color chart by providing a direct digital fluoride result.

Description

The HI729 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure fluoride.

Fluoride is one of the few chemicals that have been shown to cause significant effects in people through drinking water. Fluoride has beneficial effects on teeth at low concentrations in drinking water, but excessive exposure to fluoride in drinking water, or in combination with exposure to fluoride from other sources, can give rise to a number of adverse effects.

Water fluoridation is the controlled addition of fluoride to a public water supply to reduce tooth decay. Fluoridated water operates on tooth surfaces: in the mouth, it creates low levels of fluoride in saliva, which reduces the rate at which tooth enamel demineralizes and increases the rate at which it remineralizes in the early stages of cavities. A 1994 World Health Organization expert committee suggested a level of fluoride from 0.5 to 1.0 mg/L, depending on climate. Bottled water typically has unknown fluoride levels, and some domestic water filters remove some or all fluoride.

The HI729 Checker® is simple to use. For this measurement you need 2 vials (#1 and #2); 2 mL of reagent is added in both vials. Deionized water is then added to vial #1 while the sample to be tested is added to vial #2. Both vials are then gently inverted 5 times, and wait 2 minutes. Cuvette #1 is then inserted into the HI729 Checker® and the button pressed to zero; after that, insert cuvette #2 to take a measurement.

How to use Hanna Checker Handheld Colorimeter

Features at-a-glance:

  • Easier to use and more accurate than chemical test kits
  • Dedicated to a single parameter
  • Small size, big convenience
  • Ideal for: Drinking Water, Environmental, Industrial

Additional information

Weight 0.35 kg
Parameter

Fluoride

Specifications

SKU HI729
Name Fluoride Low-Range Checker® HC – HI729
Fluoride Range 0.00 to 2.00 ppm
Fluoride Resolution 0.01 ppm
Fluoride Accuracy ?0.10 ppm ?5% of reading
Fluoride Method adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method.
Photometer/Colorimeter Light Source LED @ 575 nm
Photometer/Colorimeter Light Detector silicon photocell
Battery Type/Life (1) 1.5V AAA
Automatic Shut-Off after ten minutes of non-use
Environment 0 to 50?C (32 to 122?F); RH max 95% non-condensing
Weight 64 g (2.25 oz.)
Dimensions 81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)

Ordering Info

HI729 Checker® is supplied with (2) sample cuvettes with caps, fluoride LR reagent starter kit for 5 tests (1 bottle of fluoride LR reagent, 30 mL), (1) 1 mL syringe with tip, battery, instructions and quick start guide.

Manuals