HI76310 EC/TDS Probe for HI2300

R12,574.00 Excl VAT

SKU: HI76310 Category

Availability on Request

The HI76310 is a platinum, four-ring EC/TDS probe with a built-in temperature sensor.

  • For use with HI2300 Autoranging Bench Meter
  • Operates over a wide range from 0.00 µS/cm to 500.0 mS/cm
  • 3.5 mm (1/8”) connector and 1 m (3.3’) cable

Description

“EC” stands for Electrical Conductivity. Electrical conductivity is defined as the ability of a substance to conduct an electrical current. Conductivity in a solution is directly proportional to the concentration of salts. Conductivity is temperature dependent and will rise in proportion to a temperature increase.

EC is recorded in mS (milliSiemens) or µS (MicroSiemens).

1 mS = 1000 µS

TDS (Total Dissolved Solids) is a proportion of EC and is usually recorded in ppm (parts per million). Three common proportion multiplying factors are: 0.7 (hydroponics), 0.64 (soil science), and 0.5 are used to convert EC to TDS. For example, if the measured EC is 1000 µS, this can be converted by multiplying it by 0.7 (hydroponics) which equals 700 ppm.

Four-ring conductivity probes utilize a potentiometric approach to measure EC. An alternating current is applied to the outer two “drive” electrodes to induce a current in the solution. The voltage is measured between the inner pair of electrodes in solution. The voltage is proportional the conductivity of the sample. This technology extends the linear range of measurement, and reduces polarization effects.

The four-rings in the HI76310 are made with platinum and the body of the electrode is made of Polyetherimide (PEI) plastic that is resistant to many harsh chemicals. The four-ring design allows for this probe to be used over a wide range of measurements.

Additional information

Weight 0.45 kg
Parameter

Conductivity/TDS

Specifications

SKU HI2003-01
Name ? Dedicated Conductivity/TDS/Salinity Meter – HI2003
EC Range 0.00 to 29.99 µS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 µS/cm, 0.1 µS/cm, 1 µS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ?1% of reading (?0.05 µS/cm or 1 digit, whichever is greater)
EC Calibration 1 point offset calibration (0.00 µS/cm in air), 1 point slope calibration in EC standard 84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ?1% of reading (?0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100? C (23 to 212? F); NoTC – none absolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ?C (for EC and TDS only). Default value is 1.90% / ?C
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)
Salinity (% NaCl) Range 0.0 to 400.0% NaCl
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ?1% of reading
Salinity (% NaCl) Calibration Single point with HI 7037L Standard
Salinity (PSU) Range 2.00 to 42.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ?1% of reading
Salinity Range 0.0 to 80.0 g/L*
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ?1% of reading
Temperature Range -20.0 to 120.0 ?C ; -4.0 to 248.0 ?F**
Temperature Resolution 0.1 ?C; 0.1 ?F
Temperature Accuracy ?0.5 ?C; ?0.9 ?F
EC/TDS Probe HI763100 EC/temperature probe
Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging Memory Up to 1000 records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
GLP yes
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Environment 0 to 50?C (32 to 122?F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)

Ordering Info

?EC HI2003 includes: HI763100 Conductivity probe, 4 sachets of 1413 µS/cm conductivity standard, 2 sachets of 5000 µS/cm conductivity standard, 2 sachets of 12880 µS/cm conductivity standard, 2 sachets general purpose rinse solution, benchtop docking station with electrode holder, wall-mount cradle, USB cable, 5 VDC power adapter, quality certificate and instruction manual.

Manuals

? Dedicated Conductivity/TDS/Salinity Meter – HI2003