ORP Analog Controller with Self-Diagnostic Test – HI8720

R20,762.00 Excl VAT

Availability on Request

HI8720 ORP panel mounted controller is ideal for process control monitoring in a wide range of industrial applications, allowing for the selection of a set point for oxidizing or reducing dosage.

  • Auto-diagnostic tests for electrode and instrument status.
  • Displays values on the easy to read LCD.
  • A removable, transparent splash-proof cover protects the front panel.

Description

Auto-Diagnostic Feature

Built-in autodiagnostic functions to enable the user to check and troubleshoot any malfunctions. The functions are made via front panel keys to isolate the cause of malfunction.

Consent Contacts

These contacts (maximum 2A, 220 V) are for reduction and oxidation reactions when the pH controller is used with an ORP Controller. In these applications, the consent contacts of both meters are connected together to link the ORP and pH controllers so that ORP dosage will occur only if the actual pH value is correct, to avoid overdosage of oxidants or reductants that can lead to pollution.

Alarm Contacts

If the measured ORP is not within the tolerance of the set value, the alarm contact is closed. This can occur if there is insufficient dosage or if there is overdosage.

Outputs

You can choose the output configuration for connecting a recorder or a PLC, between 0-20 or 4-20 mA

ORP Dosing Consent Device

When used in conjunction with the HI 8710 pH controller, the ODCD (ORP dosing consent device) function (featured by the HI 8710) will ensure that the ORP dosage will start only when the pH level is correct.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

Additional information

Weight 0.45 kg
Parameter

ORP

Specifications

SKU HI8720
Name ORP Analog Controller with Self-Diagnostic Test ??HI8720
mV Range ?1000 mV
mV Resolution 1 mV
mV Accuracy ?0.5%
mV (ORP) Calibration Offset: ?2 pH with OFFSET trimmer; Slope: 80 to 110% with SLOPE trimmer
mV (ORP) Dosing Relay 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
mV (ORP) Dosing Set Point 0.00 to 14.00 pH
Alarm Relay Set Point 1, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
Alarm Relay Range 10 to 300 mV
Over Dosing Control Adjustable, from 5 min to 60 min with knob or Disable by wire strap ? on rear panel
Analog Input Signal 4 to 20 mA
Analog Ouput Signal ?5 Vcc; 150 mA max load for amplified electrodes
Backlight Continuous ON
Enclosure Black anodized aluminum body; front and back with ABS; transparent splash?proof front cover
Power Supply 115 or 230 Vac; 60/50 Hz
Environment ?10 to 50 ?C (14 to 122 ?F); RH max 95% non condensing
Dimensions 141 x 69 mm (5.6 x 2.7”)
Weight 1 kg (2.2 lb.)