Phenols reagent (13mm Vial) - HI96788-25

R3,262.00 Excl VAT

Availability on Request

The HI96788-25 are replacement reagents for the colorimetric determination of Phenols. There are enough vials for approximately 25 tests to be used with Hanna’s HI801 and HI802 spectrophotometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date for traceability.

• Pre-made reagents for ease of use
• Prepared with high-purity chemicals
• Marked with expiration date and lot number

Description

The HI96788-25 are replacement reagents for the colorimetric determination of Phenols. There are enough vials for approximately 25 tests to be used with Hanna’s HI801 and HI802 spectrophotometers. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date for traceability.

 

11 Reasons to Choose Hanna

1.) 4-aminoantipyrine method compliant with ISO 6439 and EPA 420.1 (after distillation)
2.) Provided with Certificate of Analysis – Each pack of reagents is accompanied by a Hanna quality certificate.
3.) Very sensitive for values below 0.10 ppm
4.) Very representative sample: 5 mL
5.) Zeroing with the sample eliminates interferences (color, turbidity)
6.) Storage at room temperature
7.) Long shelf life of the reagent: 4 years
8.) Ease of test execution
9.) Space-saving packaging with procedure guide on inside lid
10.) Safe and Economical – Hanna reagents are safe for the operator and the environment. In fact, vials and caps have been designed to avoid accidental spills. Thanks to the reagents in pre-measured vials, the amount of chemicals used is reduced to a minimum.
11.) Pre-measured Vials – Each vial requires only the addition of the sample or blank.

 

Primary Applications:
Water, wastewater, surface water, formulations, degreasing baths, wash solutions, process
analysis


			

Specifications

Range 0.00 to 5.00 mg/L
Resolution 0.01 mg/L
Accuracy  ±0.05 mg/L ±3 % of reading at 25 °C
Wavelength  510 nm
Cuvette Type  13 mm diameter
Method Adaptation of 4‑aminoantipyrine Method EPA 420.1
Method  ID #097 (HI801/HI802 iris)

Accessories

HI731318 Cloth for wiping cuvettes (4 pcs.)
HI93703-50 Cuvette cleaning solution, 230 mL
HI731311 Vial 13 mm diam (5 pcs.)

Ordering Information

HI96788-25 Phenols reagent for 25 tests.