Hanna Instruments Worldwide
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +27 (0) 11 615-6076
Hanna Instruments Worldwide
Customer Support: +1 (800) 426-6287

Waterproof Portable EC/TDS/Resistivity/Salinity Meter - METER ONLY! - (HI98192-03)

R13,876.00 Excl VAT

Availability on Request

The HI98192 is a rugged, portable EC/TDS/Resistivity/Salinity meter with the performance and features of a benchtop. This professional, waterproof meter complies with IP67 standards. The HI98192 is supplied complete with all accessories to perform an EC/TDS/ Resistivity/Salinity measurement packaged into a durable carrying case.

  • Four Ring Probe
  • Quick Connect
  • Ergonomic, One-Handed Operation

Description

The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.

HI98192 has an expanded conductivity range from 0.000 µS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.

HI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.

Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.

EC and TDS measurements are fully customizable and include:

  • Cell constant selection between 0.0 and 10.000
  • Selection of linear or non-linear (natural water), or No temperature compensation

The temperature compensation coefficient range is configurable from 0.00 to 10.00%/℃ with a choice of reference temperatures of 15℃, 20℃ and 25℃. The conductivity to TDS factor is adjustable from 0.40 and 1.00.

The HI98192 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.

The log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.

GLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.

Access help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.

The compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter, probe, beakers and conductivity standards.

On-screen Features

Three stages of conformity
Performs all 3 stages of USP water quality testing requirements.

On-screen guide
Users are provided with on-screen instructions for each USP stage

USP 2 progress

Progress bar
Displays progress towards meeting stage 2 stability requirements.

Features/Benefits:

Compact, rugged, waterproof (IP67) design

Methods

  • USP <645> capable for checking the quality of water used in pharmaceutical manufacturing

Salinity readings

  • Seawater salinity can be displayed as % NaCl, natural seawater scale (ppt) or practical salinity scale (PSU)

Auto-ranging and fixed range options

Calibration

  • Perform up to a five point calibration for enhanced accuracy

GLP Features

  • GLP data provides calibration data including date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS)

Calibration timeout to alert the user at a defined interval when the calibration has expired

Auto Hold

  • Freezes first stable reading on the display

Multiple language selection

Temperature compensation

  • No temperature compensation, linear temperature compensation and non-linear temperature compensation – ISO/DIN 7888
  • Configurable linear temperature compensation coefficient range from 0.00 to 10.00%/℃

Data logging

  • Log on Demand: Store measurement data at the press of a button
  • Interval lot logging: Log measurements at a selectable interval

Connectivity

  • PC connectivity via opto-isolated USB with optional HI92000 software

100-hour battery life

  • Approximately 100 hours of continuous use (without backlight)

Menu driven for ease of use with virtual-key extended functionality

Contextual help at the press of a button

Backlit, Graphic LCD

Connectivity

  • PC connectivity via a sealed opto-isolated micro USB and HI92000 software

PRIMARY APPLICATIONS: Environmental, pharmaceutical, plating, water treatment, food manufacturing, and water and wastewater

Video

 

Additional information

Weight 2.68 kg
Parameter

Conductivity/TDS, Resistivity, Salinity

EC Accuracy

±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater)

EC Calibration

1.413 mS/cm, 111.8 mS/cm), 12.88 mS/cm, 5.00 mS/cm, 80.0 mS/cm, 84.0 µS/cm, automatic up to five points with seven memorized standards (0.00 µS/cm

EC Range

0.000 to 9.999 µS/cm*; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)

EC Resolution

0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm

TDS Accuracy

±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)

TDS Range

0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)

TDS Resolution

0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)

Temperature Accuracy

±0.2°C; ±0.4°F (excluding probe error)

Temperature Range

-20.0 to 120.0°C (-4.0 to 248.0°F)

Specifications

SKU HI98192-03
Name Waterproof Portable EC/TDS/Resistivity/Salinity Meter – HI98192
EC Range 0.000 to 9.999 µS/cm*; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated to 400 mS/cm)
EC Resolution 0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy ?1% of reading (?0.01 µS/cm or 1 digit, whichever is greater)
EC Calibration automatic up to five points with seven memorized standards (0.00 µS/cm, 84.0 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy ?1% of reading (?0.05 mg/L (ppm) or 1 digit, whichever is greater)
EC/TDS Temperature Compensation noTC, Linear (-20 to 120 ?C; -4 to 248?F), Non Linear – ISO/DIN 7888 (-0 to 36 ?C; 32 to 96.8?F)
Temperature Correction Coefficient 0.00 to 10.00 %/?C
EC to TDS Conversion Factor 0.40 to 1.00
Reference Temperature 15?C, 20?C and 25?C
EC/TDS Multi-range Measurement Modes autorange, autoend, lock and fixed range
Salinity (% NaCl) Range 0.0 to 400.0%
Salinity (% NaCl) Resolution 0.1%
Salinity (% NaCl) Accuracy ?1% of reading
Salinity (% NaCl) Calibration max. one point only in % range (with HI7037 standard)
Salinity (PSU) Range 0.00 to 42.00 (PSU)
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ?1% of reading
Salinity (PSU) Calibration based on conductivity calibration
Salinity Range 0.00 to 80.00 (ppt)
Salinity Resolution (ppt) 0.01 ppt
Salinity Accuracy (ppt) ?1% of reading
Salinity Calibration (ppt) based on conductivity calibration
Resistivity Range 1.0 to 99.9 ? cm; 100 to 999 ? cm; 1.00 to 9.99 K? cm; 10.0 to 99.9 K? cm; 100 to 999 K? cm; 1.00 to 9.99 M? cm; 10.0 to 100.0 M? cm
Resistivity Resolution 0.1 ? cm; 1 ? cm; 0.01 K? cm; 0.1 K? cm; 1 K? cm; 0.01 M? cm; 0.1 M? cm*
Resistivity Accuracy ?1% of reading (?10 ? or 1 digit, whichever is greater)
Temperature Range -20.0 to 120.0?C (-4.0 to 248.0?F)
Temperature Resolution 0.1?C (0.1?F)
Temperature Accuracy ?0.2?C; ?0.4?F (excluding probe error)
EC/TDS Probe HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)
Logging Type Log-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Logging Memory up to 10
Connectivity opto-isolated USB with optional HI 92000 software and micro USB cable
Automatic Shut-Off user selectable: 5, 10, 30, 60 min or can be disabled
Battery Type/Life 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Environment 0 to 50?C (32 to 122?F); RH 100% (IP67)
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 400 g (14.2 oz.)

Ordering Info

 

HI98192 meter only version, with carrying case

Download