  • HI98494
Multiparameter Bluetooth® Portable pH/EC/OPDO® Meter pH, ORP, EC, TDS, Resistivity, Salinity,... more
Product information "HI98494 Multi-parameter Bluetooth® portable PH/EC/OPDO meter with HI7698494/4 (4m cable)"

Multiparameter Bluetooth® Portable pH/EC/OPDO® Meter

pH, ORP, EC, TDS, Resistivity, Salinity, Seawater ?, Dissolved Oxygen, Atmospheric Pressure and Temperature
HI98494 is a waterproof portable logging multiparameter meter that monitors up to 12 different water quality parameters including 6 measured and 6 calculated.  The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, and temperature. The probe transmits readings digitally to the meter, where data points can be displayed and logged. Data logged in the meter can be transferred by Bluetooth® to a smart device with the Hanna Lab App installed. The HI98494 is supplied with all necessary accessories and packaged in a durable carrying case.

Designed to withstand environmental conditions, and ideal for field measurements. The HI98494 instruments is a waterproof combination of a portable, rugged meter with a digital probe. The probe can be manually lowered and raised by the cable, due to its superior strength.  The digital probe is suitable for confined locations (air vaults, river intakes, vertical wells) and tanks. It can be used in open moving water locations, such as rivers, streams, ditches (farmland drainage) and conveyance canals as well as lakes, dams, ponds, wetland basins, infiltration basins and bays.

  • Bluetooth® Connectivity
  • OPDO: Optical Dissolved Oxygen Technology
  • 12 Parameter Dot Matrix Display

APPLICABLE MARKETS

  • Environmental
    • Ecologist/Researchers
      • Studying lakes, streams and ocean water
  • Aquaculture
    • Monitoring water quality
      • pH and DO are most important
  • Waste Water Treatment (Municipal)
    • Monitoring points for pH/EC/DO include:
      • Aeration (oxidation) tanks 
      •  
        Outfall (discharge) for environmental compliance
  • Drinking Water
    • Parameters measured impacted by source
      • Surface water
      • Groundwater
  • EPA Method 150.1
      • Automatic or manual temperature compensation
  • Food & Beverage
    • Wastewater Treatment
      • Monitoring of pre-treatment program

 

PARAMETERS AVAILABLE

  • SENSORS

    • •pH
    • •ORP
    • •EC
    • •DO Saturation
    • •Temperature
    • •Atmospheric Pressure
  • INTERPRETATIVE PARAMETERS

    • PH-mV
    • Absolute Conductivity
    • Resistivity
    • Total Dissolved Solids
    • Salinity
    • Seawater Simga
    • DO Concentration

HI98494-Image


Bluetooth connectivity

  • Retrieve data logs with Hanna Lab app for either sending by e-mail or download to a smart device for review

Waterproof

IP67 rated waterproof, rugged enclosure for meter, IP68 for probe

Digital probe

    • Digital probe with built-in temperature sensor and three ports for pH (ORP), EC and optical DO sensors
    • Color coded, field replaceable sensors
    • Auto-sensor recognition
    • Stainless steel, weighted protective guard

Quick calibration feature
Automatic barometric pressure compensatio

Automatic temperature compensation

Logging

    • Automatic interval logging of up to 45,000 samples
    • Log-on-demand to store measurement data

GLP

    • GLP data provides data from previous five calibrations to ensure Good Laboratory Practices are met

Dedicated help key

    • On-screen context specific help is readily available at the press of a button

Backlit LCD display with multifunction virtual keys

Intuitive keypad

    • Dedicated and virtual soft keys

USB type-C

    • Computer connectivity for transferring logged data as .CSV file
      Port used for recharging built-in lithium-ion battery

Dual power source

    • Meter operates on built-in lithium-ion battery
    • Meter automatically switches to common alkaline batteries as backup power source

Bluetooth® and Hanna Lab App Compatibility

Measurements & Logging

Measure up to 12 parameters. Don't lose important data with automatic interval logging of up to 45,000 samples or choose to log-on-demand to store measurement data for key points.

Dual Power Source

The meter operates on a built-in lithium-ion battery and will automatically switch to AA alkaline batteries for at least 200 hours of testing.

GLP Data

For better traceability, calibration information is recorded along with a time and date stamp and stored with logged data.

Quick-Calibration

Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are also available.

Multiparameter Probe and Sensors

HI7698494-probe_extremeangle_full

Multi-function Sensor

  • Quick sensor replacement
  • Sensor replacement is quick and easy with field replaceable, screw type connectors and are color coded for easy identification. These meters automatically recognize sensors.

Optical-DO-Smart-Caps-for-HI98494

 

All models are supplied with:
HI7698194-1 pH/ORP sensor, HI7698194-3 EC sensor, HI7698295 short protective probe shield, HI7698494-5 optical DO sensor, HI9828-20 quick calibration solution, zero oxygen solution, HI76984942 probe maintenance kit, HI920016 USB type-C cable, HI7698290 calibration beaker, batteries (4), quality certificate, and instruction manual in a rugged carrying case with custom insert.

Accessories
HI710034 orange protective rubber boot

Optional Cable lengths

  • HI98494 is supplied with HI7698494/4 multiparameter probe with 4m cable
  • HI98494/10 is supplied with HI7698494/10 multiparameter probe with 10m cable
  • HI98494/4098494/20 is supplied with HI7698494/20 multiparameter probe with 20m cable
  • HI98494/40 is supplied with HI7698494/40 multiparameter probe with 40m cable

 

SPECIFICATIONS

 
pH Range 0.00 to 14.00 pH*
pH Resolution 0.01 pH
pH Accuracy ± 0.02 pH
pH Calibration one point, using HI9828-25 Quick calibration solution up to three points using five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) and one custom buffer
pH Temperature Compensation automatic from -5 to 50 °C (23 to 122 °F)
ORP Range ± 2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ± 1.0 mV
ORP Calibration one point (relative mV)
mV Range pH in mV ± 600.0 mV
mV Resolution pH in mV 0.1 mV
mV Accuracy pH in mV
mV Relative Offset ± 0.5 mV
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01
EC Accuracy ±1 % of reading or ±1 ?S/cm, whichever is greater
EC Calibration One point, using HI9828-25 Quick calibration solution One point, using six standard solutions (84 ?S/cm, 1413 ?S/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)
TDS Resolution manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt)
TDS Accuracy ±1 % of reading or ±1 ppm (mg/L), whichever is greater
TDS Calibration Based on conductivity calibration
EC/TDS Temperature Compensation automatic from -5 to 50 °C (23 to 122 °F)
Temperature Correction Coefficient 0.00 to 6.00 %/°C
EC to TDS Conversion Factor 0.00 to 1.00
Reference Temperature 20 °C or 25 °C
Cell Type potentiometric four pole
EC/TDS Multi-range Measurement Modes yes
Salinity (PSU) Range 0.00 to 70.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±2% of reading or ±0.01 PSU, whichever is greater
Salinity (PSU) Calibration One point, using a custom solution
Salinity (Seawater Sigma) Range 0.0 to 50.0 ?t, ?0, ?15
Salinity (Seawater Sigma) Resolution 0.1 ?t, ?0, ?15
Salinity (Seawater Sigma) Accuracy ±1.0 ?t, ?0, ?15
Salinity (Seawater Sigma) Calibration Based on conductivity or salinity calibration
Resistivity Range 0 to 999999 ?·cm
Resistivity Resolution 1 ?·cm; 0.1 k?·cm; 0.0001 M?·cm
Resistivity Calibration Based on conductivity or salinity calibration
Dissolved Oxygen Measurement Type optical luminscent technology
Dissolved Oxygen Range 0.00 to 50.00 mg/L
0.0 to 500.0 % saturation
Dissolved Oxygen Resolution 0.01 mg/L
0.1 % saturation
Dissolved Oxygen Accuracy ±1.5 % of reading ± 0.01 mg/L from 0.00 to 20.00 mg/L
±5 % of reading from 20.00 to 50.00 mg/L
±1.5 % of reading ±0.1 % from 0.0 to 200.0 % saturation
±5 % of reading from 200.0 to 500.0 % saturation
Dissolved Oxygen Calibration one point, quick calibration in water-saturated air
One or two points, at 100 % and 0 %
One point, using a custom solution (% saturation or mg/L )
Dissolved Oxygen Temperature Compensation automatic from -5 to 50 °C (23 to 122 °F)
Altitude Compensation automatic: 420 to 850 mmHg
Atmospheric Pressure Range 450.0 to 850.0 mmHg 17.72 to 33.46 inHg 600.0 to 1133.2 mbar 8.702 to 16.436 psi 0.5921 to 1.1184 atm 60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mmHg; 0.01 in Hg; 0.1 mbar 0.001 psi; 0.0001 atm; 0.01 kPa
Atmospheric Pressure Accuracy ±3.0 mmHg within ±15°C from calibration temperature
Atmospheric Pressure Calibration One point using a custom value
Temperature Range -5.00 to 50.00 °C, 23.00 to 122.00 °F, 268.15 to 323.15 K
Temperature Resolution 0.01 °C; 0.01 °F; 0.01 K
Temperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 K
Temperature Calibration One point using a custom value
pH Electrode HI7698194-0
pH/ORP Electrode HI7698194-1 (supplied)
EC/TDS Probe HI7698194-3 (supplied)
DO Probe HI7698494-5 (supplied)
Multi-parameter Probe HI7698494 (supplied)
Temperature Probe built-in
Logging Type interval and log on demand
Logging Memory 50000 records, interval logging
20000 records, log-on-demand of all parameters
Logging Interval 1 second to 3 hours
Connectivity Bluetooth®, USB-C (mass-storage host), USB-C (mass-storage device)
Automatic Shut-Off 5, 10, 15, 20, 30, 60 minutes or disabled
GLP yes
Display backlit dot matrix
Battery Type/Life Minimum 200 hours (AA batteries, without backlighting and Bluetooth®)
Minimum 50 hours (Li-ion battery, without backlighting and Bluetooth®)
IP Protection IP67
Environment 0 to 50 °C (32 to 122 °F); RH 100 %
Dimensions 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 435 g (13.3 oz)
Ordering Information HI98494 is delivered in a rugged thermoformed carrying case and is supplied with, HI7698494 multi-sensor probe, HI7698194-1 pH/ORP sensor, HI7698194-3 EC/TDS/Resistivity/Salinity sensor, HI7698494-5 optical DO sensor, HI764113-1 DO smart cap with o ring, HI7698295 short protective probe shield, HI7698290 calibration beaker, HI9828-20 quick calibration standard solution (230 mL), HI7040 Zero oxygen solution set (120 mL), HI76984942 probe maintenance kit, HI920016 USB cable, 1.5V AA alkaline batteries (4 pcs.), instrument quality certificate, probe quality certificate, DO smart cap quality certificate, and instruction manual.
Notes *The range may be limited by the sensor’s limits.

 

 

Related links to "HI98494 Multi-parameter Bluetooth® portable PH/EC/OPDO meter with HI7698494/4 (4m cable)"
Available downloads:
Read, write and discuss reviews... more
Customer evaluation for "HI98494 Multi-parameter Bluetooth® portable PH/EC/OPDO meter with HI7698494/4 (4m cable)"
Write an evaluation
Please enter these characters in the following text field.

The fields marked with * are required.

Hint!
Viewed