® edge Dedicated Conductivity/TDS/Salinity Meter (HI2003-02)

R13,704.00R22,578.00 Excl VAT

Hanna Instruments is proud to introduce the world’s most innovative Conductivity/TDS/Salinity meter: edge®.

edge®’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world-class R&D. edge® is a single meter that can measure Conductivity, TDS and Salinity and is incredibly easy to use.

four ring conductivity probe

Four ring conductivity Probe

edge® EC/TDS/Salinity utilizes four ring conductivity probe technology that allows the user to measure samples from very low conductivity to very high conductivity. edge® is an auto-ranging meter that will select the appropriate range for the measurement to ensure the highest accuracy available.

Capacitive Touch

Capacitive Touch

edge® features a capacitive touch keypad that gives a distinctive, modern look. The keypad is sensitive enough to be used with laboratory gloves and has a fast response. Since the keypad is part of the screen, there are no buttons to get clogged with sample residue.

Clear Full Text Readout

Large Easy to Read LCD

edge® features a 5.5” LCD display that you can clearly view from over 5 meters away. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCD’s in the industry.

Description

edge Conductivity/TDS/Salinity In Cradle

edge® Conductivity/TDS/Salinity is packed with many cutting-edge features to ensure accuracy and usability.

four ring conductivity probe

Digital EC Electrode

edge® EC electrode is highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge® once the electrode is plugged in. Information stored in the electrode includes model number, serial number and calibration information including the standards used and the date and time the last calibration was performed.

Capacitive Touch

Four Ring Probe

The edge® EC/TDS/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that has a built-in temperature sensor for automatic temperature compensated measurements. The four ring technology allows for a wide range of measurement with a single probe as compared to amperometric two pole probes that have a limited range and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide) sleeve. Both materials have excellent resistance against many aggressive chemicals.

probe input

3.5 mm Probe Input

Plugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.

 

hi2002 edge Conductivity/TDS/Salinity meter wall mount

edge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.

wall mount

Wall Mount

Using the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built in connector to power edge and charge its batteries. edge’s zero footprint design saves you valuable benchtop space.

Cradle

Cradle and Electrode Holder

edge® is equipped with a benchtop cradle featuring an adjustable swivel electrode holder to charge and hold the meter securely in place at the optimum viewing angle.

edge thin pH meter handheld

edge® is incredibly thin and weighs only 8.8 oz., has an 8-hour battery life, and dual USB inputs.

usb

Two USB Ports

edge® includes one standard USB for exporting data with a flash drive and a second micro-USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.

data logging

 

Data Logging

edge® allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.

basic mode

Two Operating Modes

edge® offers both Basic and Standard Modes. In Basic Mode, the edge as an EC meter reduces features to simplify operation. In Basic Mode, the meter will only allow for automatic temperature compensation, auto ranging of readings, and automatic cell factor correction while calibrating. The temperature correction coefficient is fixed to 1.9% / ℃ and interval logging is not available. In Standard Mode, the user has options to change these settings.

Video

 


Additional information

Weight 2.7 kg
Parameter

Conductivity/TDS, Salinity

EC Accuracy

±1% of reading (±0.05 µS/cm or 1 digit, whichever is greater)

EC Calibration

1 point offset calibration (0.00 µS/cm in air), 1 point slope calibration in EC standard 84 µS/cm, 12.88 mS/cm, 1413 µS/cm, 5.00 mS/cm, 80.0 mS/cm and 111.8 mS/cm

EC Range

0.00 to 29.99 µS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, 30.0 to 299.9 µS/cm, 300 to 2999 µS/cm, up to 500.0 mS/cm (absolute EC)**

EC Resolution

0.01 mS/cm, 0.01 µS/cm, 0.1 mS/cm, 0.1 µS/cm, 1 µS/cm

TDS Accuracy

±1% of reading (±0.03 ppm or 1 digit, whichever is greater)

TDS Calibration

through EC calibration

TDS Range

0.00 to 14.99 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), up to 400.0 g/L (absolute TDS)**

TDS Resolution

0.01 g/L, 0.01 ppm, 0.1 g/L, 0.1 ppm, 1 ppm

Temperature Accuracy

±0.5 ºC; ±0.9 ºF

Temperature Range

-20.0 to 120.0 ºC ; -4.0 to 248.0 °F**

Options Available

"Kit", "Meter only, no accessories"

Specifications

SKU HI2003-02
Product Name edge® Dedicated Conductivity/TDS/Salinity Meter – HI2003
Quote Required Yes
EC Range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm, 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm, up to 500.0 mS/cm (absolute EC)**
EC Resolution 0.01 μS/cm, 0.1 μS/cm, 1 μS/cm, 0.01 mS/cm, 0.1 mS/cm
EC Accuracy ±1% of reading (±0.05 μS/cm or 1 digit, whichever is greater)
EC Calibration 1 point offset calibration (0.00 μS/cm in air), 1 point slope calibration in EC standard 84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm and 111.8 mS/cm
TDS Range 0.00 to 14.99 ppm (mg/L), 15.0 to 149.9 ppm (mg/L), 150 to 1499 ppm (mg/L), 1.50 to 14.99 g/L, 15.0 to 100.0 g/L, up to 400.0 g/L (absolute TDS)**
TDS Resolution 0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.03 ppm or 1 digit, whichever is greater)
TDS Calibration through EC calibration
EC/TDS Temperature Compensation Automatic -5 to 100º C (23 to 212º F); NoTC – none absolute conductivity.
Temperature Correction Coefficient 0.00 to 6.00% / ºC (for EC and TDS only). Default value is 1.90% / ºC
EC to TDS Conversion Factor 0.40 to 0.80 (default value is 0.50)
Salinity (% NaCl) Range 0.0 to 400.0% NaCl
Salinity (% NaCl) Resolution 0.1% NaCl
Salinity (% NaCl) Accuracy ±1% of reading
Salinity (% NaCl) Calibration Single point with HI 7037L Standard
Salinity (PSU) Range 2.00 to 42.00 PSU
Salinity (PSU) Resolution 0.01 PSU
Salinity (PSU) Accuracy ±1% of reading
Salinity Range 0.0 to 80.0 g/L*
Salinity Resolution (ppt) 0.01 g/L
Salinity Accuracy (ppt) ±1% of reading
Temperature Range -20.0 to 120.0 ºC ; -4.0 to 248.0 °F**
Temperature Resolution 0.1 ºC; 0.1 ºF
Temperature Accuracy ±0.5 ºC; ±0.9 ºF
EC/TDS Probe HI763100 EC/temperature probe
Logging Type Manual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs/lot
Logging Memory Up to 1000 records
Connectivity 1 micro USB port for charging and PC connectivity, 1 USB port for storage
GLP yes
Battery Type/Life Built-in rechargeable battery with up to 8 hours of continuous use
Power Supply 5 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Dimensions 202 x 140 x 12.7mm (8” x 5.5” x 0.5”)
Weight 250 g (8.82 oz)
Ordering Information edge®EC HI2003 includes
Notes * Not available in basic mode

Ordering Info

EC HI2003 includes: HI763100 Conductivity probe, 4 sachets of 1413 µS/cm conductivity standard, 2 sachets of 5000 µS/cm conductivity standard, 2 sachets of 12880 µS/cm conductivity standard, 2 sachets general purpose rinse solution, benchtop docking station with electrode holder, wall-mount cradle, USB cable, 5 VDC power adapter, quality certificate and instruction manual.