SKU |
HI98195/40 |
Name |
Multiparameter pH/ORP/EC/Pressure/Temperature Waterproof Meter – HI98195-40m (131.2′) |
pH Range |
0.00 to 14.00 pH |
pH Resolution |
0.01 pH |
pH Accuracy |
?0.02 pH |
pH Calibration |
automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
ORP Range |
?2000.0 mV |
ORP Resolution |
0.1 mV |
ORP Accuracy |
?1.0 mV |
ORP Calibration |
automatic at one custom point (relative mV) |
mV Range |
?600.0 mV |
mV Resolution |
0.1 mV |
mV Accuracy |
?0.5 mV |
EC Range |
0 to 9999 µS/cm; 0.000 to 200.0 mS/cm (absolute EC up to 400.0 mS/cm) |
EC Resolution |
auto-ranging: 1 µS/cm from 0 to 9999 µS/cm; 0.01 mS/cm from 10.00 to 99.99 mS/cm; 0.1 mS/cm from 100.0 to 400.0 mS/cm; auto-ranging (fixed mS/cm): 0.001 mS/cm from 0.000 to 9.999 mS/cm; 0.01 from 100.0 to 400.0 mS/cm ; manual: 1 µS/cm; 0.001 mS/cm; 0.01 |
EC Accuracy |
?1% of reading or ?1 µS/cm whichever is greater |
EC Calibration |
automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range |
0 to 9999 ppm (mg/L); 0.000 to 400.0 ppt (g/L) (maximum value depends on TDS factor) |
TDS Resolution |
manual: 1 ppm (mg/L); 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L); 1 ppt (g/L); auto-ranging: 1 ppm (mg/L) from 0 to 9999 ppm (mg/L); 0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L); 0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L); auto-ranging (fixed ppt): |
TDS Accuracy |
?1% of reading or ?1 ppm (mg/L), whichever is greater |
TDS Calibration |
based on conductivity calibration |
Salinity (PSU) Range |
0.00 to 70.00 PSU |
Salinity (PSU) Resolution |
0.01 PSU |
Salinity (PSU) Accuracy |
?2% of reading or ?0.01 PSU whichever is greater |
Salinity (PSU) Calibration |
based on conductivity calibration |
Salinity (Seawater Sigma) Range |
0.0 to 50.0 ?t, ??, ??? |
Salinity (Seawater Sigma) Resolution |
0.1 ?t, ??, ??? |
Salinity (Seawater Sigma) Accuracy |
?1 ?t, ??, ??? |
Salinity (Seawater Sigma) Calibration |
based on conductivity calibration |
Resistivity Range |
0 to 999999 ? cm; 0 to 1000.0 k? cm; 0 to 1.0000 M? cm |
Resistivity Resolution |
dependent on resistivity reading |
Resistivity Calibration |
based on conductivity calibration |
Temperature Range |
-5.00 to 55.00 ?C, 23.00 to 131.00 ?F, 268.15 to 328.15 K |
Temperature Resolution |
0.01 K, 0.01 ?C, 0.01 ?F |
Temperature Accuracy |
?0.15 ?C; ?0.27 ?F; ?0.15 K |
Temperature Calibration |
automatic at one custom point |
Temperature Compensation |
automatic from -5 to 55 ?C (23 to 131 ?F) |
Logging Memory |
45,000 records (continuous logging or log-on-demand of all parameters) |
Logging Interval |
one second to three hours |
Connectivity |
USB to PC with HI9298194 Hanna software installed |
Battery Type/Life |
1.5V AA batteries (4) / approximately 360 hours of continuous use without backlight (50 hours with backlight) |
Environment |
0 to 50?C (32 to 122?F); RH 100% (IP67) |
Dimensions |
185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”) |
Weight |
400 g (14.2 oz.) |