Karl Fischer Volumetric Titrator (HI933-02)

R240,865.00 Excl VAT

Availability on Request

Our Karl Fischer Volumetric Titrator (HI933) is perfect for scientists and industry professionals alike. Test confidently and measure moisture content with precision. This titrator will automatically detect and determine the exact water content of a sample (range 100 ppm to 100%). Achieve accurate, reliable results at just the push of a button. 

Our Karl Fischer Volumetric Titrator is a smart investment for laboratories or businesses. Ensure peace of mind for the long term, meet requirements, and adhere to stringent quality standards.    

  • Dependable and consistent. Get precise and exact moisture results  
  • Durable and compact. Built to withstand harsh chemicals and takes up less bench space  
  • Safe and efficient. Reduces exposure to reagents during the testing process and saves time    

Description

Range: 100 ppm to 100%

ACCURACY CAPABILITIES

  • Equipped with a dosing pump that offers an unmatched 40,000 step accuracy
  • Save and store up to 100 titration methods (either user-defined or standard). Customize methods to fit specific application needs or testing requirements. Easily program this titrator with standard methods that are in accordance with affiliations like ISO, ASTM, AOAC, AOCS, EPA and more
  • Operators can program this titrator unit with notification reminders for when to standardize the titrant
  • This titrator automatically calculates the average titer value and users can update the nominal concentration in the sample methods with the press of a button
  • Track progress in real-time. All important information is shown on the titrator’s large LCD screen. Use the live titration curve during analysis to quickly recognize patterns and spot potential problems 
  • Achieve high speed analysis without sacrificing accuracy with dynamic titrant dosing. This occurs by adjusting the volume of titrant dosed according to the mV response from the titrator reaction 
  • Get more accurate measurements with automatic drift rate compensation. This corrects the titration calculation to account for the effects of any moisture that may enter the cell
  • Choose the endpoint termination criteria based on mV stability times or drift rates with the dual platinum pin electrode
  • Maintain data quality with the titration results averaging feature. Ideal for those operators who consistently run replicates of samples. The successive results from a titration method are averaged along with the standard deviation
  • Attain a reliable starting baseline with the multistage analysis. This works well for users that test multiple sample types with different methods for each 

 

DURABILITY AND DESIGN DETAILS

  • Manufactured to stand up to the harsh solvents and reagents used during titrations
  • Made with tough, chemically resistant materials including a strong casing as well as PFTE tubing with glass and stainless-steel components
  • Convenient-size, fits perfectly into any lab space 
  • Simple to set up and user-friendly. Perfect for labs and businesses that have multiple personnel shift changes throughout the day
  • Intuitive screens and menus help operators navigate this titrator unit easily without getting lost in a nest of information

 

SAFE AND IMPORTANT OPERATIONAL FEATURES

  • Introducing a solid or liquid sample to the titration vessel is simple and straightforward. Includes a quick-remove sample port with a replaceable rubber septum
  • Equipped with a sealed solvent management system and built-in air pumps. Users can move the reagent into waste and refill without physically touching the reagent. This makes testing seamless, eliminates manual chemical handling, and reduces the risk of contact or spills. The sealed solvent management system also mitigates excess moisture from getting into the cell 
  • Standby mode keeps the solvent dry between titrations or when the titrator is not in use  
  • Includes a rechargeable, color-indicating, silica gel desiccant. The desiccant changes color to alert users when its absorption capacity is depleted and needs to be recharged or replaced

REPORTING AND CONNECTION OPTIONS

  • Tailor titration reports and store required Good Laboratory Practice (GLP) data
  • Export and transfer data to a USB flash drive or PC using the HI900PC application software
  • Print titration reports directly from this titrator using a standard parallel printer
  • Attach an external keyboard for added versatility
  • Connect an analytical balance to the titrator unit with a RS232 serial output. Helps save time with automatic sample weight entry and is ideal for back-weighing purposes

 

 

We’re here for you

When you invest in a titrator with Hanna, you gain an entire team of experts ready to support you and your testing needs. We work with you every step of the way to ensure your testing success. From titrator installation and training to method customization and preventative maintenance, we’ve got you covered. Get peace of mind and keep your titrator operating at optimal performance!

 

 

 

Dynamic Titrant Dosing

The dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.

Drift Rate Compensation

The HI933 Volumetric Karl Fischer Titrator automatically adjusts the titration calculation to account for the effects of any ambient humidity entering the titration cell. This provides a more accurate result by correcting for water not present in the actual sample.

Titration Results Averaging

Successive results from a karl fischer titration method may be averaged with recording of the standard deviation.

Titrant Recordkeeping

The HI933’s titrant database can store information for up to 20 titrants. The database may be programmed to remind a user when to standardize their titrant, reducing error in analysis.

Selectable Endpoint Criteria

The HI933 employs a dual platinum pin electrode for bivoltammetric endpoint determination. Users may choose termination criteria based on mV stability times or drift rates.

Multistage Cell Preparation

A pre-titration stage eliminates residual water present in the solvent and the cell, providing a reliable baseline start to analysis. Standby mode then keeps the solvent dry between titrations and when the titrator is not in use.

 

Burettes & Dosing System

 

Be confident in your results.

Our unmatched 40,000 step piston driven dosing pump is capable of dosing extremely small and highly accurate volumes of reagent, helping you achieve a very precise endpoint.

Engineered to be strong

Aspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.

Anti-Diffusion Dispensing Tip

A specially designed glass dispensing tip delivers titrant precisely into high turbulence mixing zones, ensuring a rapid reaction. Its angular construction helps prevent titrant from diffusing into the sample solvent.

 

Titration & Solvent System

Efficient Sample Handling

The HI933 features a quick-remove sample port with a replaceable rubber septum allowing for fast and easy sample introduction to the titration vessel. An integrated magnetic stirrer ensures homogeneity for an accurate and speedy reaction.

Chemically Resistant Titration Vessel

The glass and PTFE titration cell and fittings are designed to withstand the harsh solvents and reagents involved in Karl Fischer titration.

Sealed Solvent System

The titration vessel is completely sealed to minimize exposure to ambient humidity, keep the system dry, and reduce titrant consumption while saving time between titrations. Solvent may be exchanged in a matter of seconds without opening the titration vessel.

 

Visually Recognizable Desiccant

A rechargeable, color-indicating, silica gel desiccant prevents the ingress of ambient humidity into the sealed system while maintaining full titrator functionality. The desiccant color change allows a user to recognize when it’s adsorption capacity has depleted and is ready for replacement or recharging.

 

Interface & Display

All of your important information is displayed.

Our large color display shows you everything you need to know during testing.

Track your progress in real-time.

Our live titration curve helps you quickly recognize patterns and problems that may arise during your analysis.

Explore titrator menus with ease.

Custom keys allow you to clearly navigate between screens so you don’t get lost.

 

Titrator Data & Reporting

Highlight your most important information.

Final reports are customizable so you can make sure you are viewing and storing your most important information.

Safeguard the integrity of your data.

Our software allows you to record full GLP (Good Laboratory Practice) data so there is no need to compromise the quality of your results.

Move your information easily across devices.

Use our software or a USB to conveniently transfer files between your titrator and computer.

 

Connectivity & Functionality

View and print reports easily.

You can print reports directly from the titrator with a connected printer and conveniently view results with a connected monitor.

Take advantage of the versatility.

Connect the devices that help you most, whether it be an analytical balance for automatic sample entry or a printer for your reports.

Additional information

Weight 12.19 kg

Specifications

SKU HI933-02
Product Name Karl Fischer volumetric titrator, 230V
Quote Required Yes
Titration Range 100 ppm to 100%
Titration Resolution 1 ppm to 0.0001%
Measurement Units %, ppm, mg/g, μg/g, mg, μg, mg/mL, μg/mL, mg/pc, μg/pc
Sample Type liquid or solid
Pre-Titration Conditioning automatic
Background Drift Correction automatic or user-selectable value
Endpoint Criteria fixed mV persistence, relative drift stop or absolute drift stop
Dosing Type dynamic with optional pre-dispensing
Result Statistics mean, standard deviation
Dosing Accuracy ±0.1% of full burette volume
Syringe 5 mL precision ground glass with PTFE plunger
Valve motor-driven 3-way, PTFE liquid contact material
Tubing PTFE with light block and thermal jacketing
Dispensing Tip glass, fixed position, anti-diffusing
Titration Vessel conical with operation volume between 50 and 150 mL
Solvent Handling System sealed system, integrated diaphragm air pump
Connection Type BNC
Polarization Current 1, 2, 5, 10, 15, 20, 30 or 40 uA
mV Range 2 mV to 1000 mV
mV Resolution 0.1 mV
mV Accuracy ±0.1%
Burette 5 mL burette
Dosing Pump Resolution 1/40000 of the burette volume (0.125 μL per dose) with 5 mL burette
Stirrer Type magnetic, optically regulated, digital stirre
Stirrer Speed 200 – 2000 RPM
Stirrer Resolution 100 RPM
Titrator Methods up to 100 standard and user defined
Reports up to 100 complete titration reports and drift rate reports
Connectivity USB
Built-in Magentic Stirrer magnetic, optically regulated, digital stirrer; 200 to 2000 rpm; resolution 100 rpm
Display 5.7” graphical color display with backlight
Keypad polyester
Languages English, Portuguese, Spanish, and French
Power Supply 100-240 Vac, 50/60 Hz / 0.5 Amps
Environment Operating
Dimensions 315 x 205 x 375 mm (12.4 x 8.1 x 14.8″)
Weight Approximate 4.3 kg (9.5 lbs) with 1 pump, stirrer and sensors
Ordering Information HI933 is supplied with HI76320 dual platinum pin electrode, dosing pump, 5 mL burette assembly with tubing, air pump/stirrer assembly with tubing, beaker and bottle top assemblies and all fittings, desiccant cartridges (4) with indicator desiccant, stir bar, waste bottle, calibration key, USB cable, power cable, USB flash drive, quality certificate, ISO 8655 burette compliance report, and instruction manual binder

Ordering Info

HI933 is supplied with HI76320 dual platinum pin electrode, dosing pump, 5 mL burette assembly with tubing, air pump/stirrer assembly with tubing, beaker and bottle top assemblies and all fittings, desiccant cartridges (4) with indicator desiccant, stir bar, waste bottle, calibration key, USB cable, power cable, USB flash drive, quality certificate, ISO 8655 burette compliance report, and instruction manual binder

Downloads

Download Product Manual

Whats Included

Karl Fischer Volumetric Titrator (HI933)
Karl Fischer dual platinum pin electrode (1 pc) (HI76320)
Dosing pump assembly (1 pc) (HI930100)
Burette assembly (1 pc) (HI930505)
Air pump and magnetic stirrer assembly (1 pc) (HI930180)
Beaker assembly (1 pc) (HI930520)
Beaker support (1 pc)
Pump locking screws with plastic head (2 pcs)
Titrant bottle assembly (1 pc) (HI900530)
Solvent bottle assembly (HI900531)
Waste bottle assembly (1 pc) (HI900531)
Calibration key (1 pc) (HI900941)
Power supply (1 pc) (HI900946)
USB cable (1 pc) (HI920013)
USB flash drive (1 pc) (HI930900U)
Instruction manual (1 pc) (HI930803)
Quality certificate (1 pc)
ISO 8655 burette compliance report (1 pc)