Hanna Instruments Worldwide
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +27 (0) 11 615-6076
Hanna Instruments Worldwide
Customer Support: +1 (800) 426-6287

EC Analog Controller with Input from Probe or Transmitter – HI8931

R17,781.00 Excl VAT

R17,781.00 Excl VAT

Availability on Request

R17,781.00 Excl VAT

Availability on Request

R17,781.00 Excl VAT

Availability on Request

R17,781.00 Excl VAT

Availability on Request

HI8931 series are panel mounted conductivity meters and controllers designed for simplicity of use in a wide range of industrial process applications.

  • Available in four models with different measurement ranges
  • Temperature compensation ensures fast, accurately compensated readings even during sudden temperature fluctuations
  • Backlit, LCD display for easy viewing.

Description

Measurement Specific Models

Four different models are available with different measurement ranges, each one to be used with the corresponding HI8936 model.

In-line and Tank Use

For in-line applications, the HI7635 In-line conductivity probe – NTC sensor is recommended, while the HI7638 In-line Conductivity probe with NTC sensor for immersion, with external threads, is recommended for tanks. These probes have built-in NTC sensors for temperature compensated conductivity measurements.

Automatic Temperature Compensation

Built-in temperature sensor in recommended probes ensure fast, accurately compensated readings even during sudden temperature fluctuations.

Use with Transmitter

Using the HI8931 in conjunction with a 4-20 mA output transmitter (HI8936 or HI8936L series) will assure a strong, interference free signal at distances up to 300 meters (1000’).

Direct Connection

HI8931 also features a direct connection up to 20 m (67’), without needing to amplify the signal to the conductivity probe.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

Additional information

Weight 0.45 kg
Parameter

Conductivity/TDS

EC Accuracy

±2% F.S. (excluding probe error)

EC Calibration

manual, through offset and slope trimmers, two point

EC Range

HI8931AN: 0.0 to 199.9 mS/cm HI8931BN: 0.00 to 19.99 mS/cm HI8931CN: 0 to 1999 µS/cm HI8931DN: 0.0 to 199.9 µS/cm

EC Resolution

HI8931AN: 0.1 mS/cm HI8931BN: 0.01 mS/cm HI8931CN: 1 µS/cm HI8931DN: 0.1 µS/cm

Specifications

SKU HI8931-web
Name EC Analog Controller with Input from Probe or Transmitter ? HI8931
EC Range HI8931AN: 0.0 to 199.9 mS/cm
HI8931BN: 0.00 to 19.99 mS/cm
HI8931CN: 0 to 1999 µS/cm
HI8931DN: 0.0 to 199.9 µS/cm
EC Resolution HI8931AN: 0.1 mS/cm
HI8931BN: 0.01 mS/cm
HI8931CN: 1 µS/cm
HI8931DN: 0.1 µS/cm
EC Accuracy ?2% F.S. (excluding probe error)
EC Calibration manual, two point, through offset and slope trimmers
EC/TDS Temperature Compensation automatic, 0 to 60?C (32 to 140?F), with ? = 2%/?C
Alarm Relay Set Point load, 1,000,000 strokes
Enclosure DIN 43 700, 144×72 mm (5.7×2.8 in.), black anodized aluminum; front and back with shockproof ABS plastic, and transparent cover
EC/TDS Probe HI7635 for in-line applications or HI7638 for tank (not included)
Power Supply 115 or 230 Vac ?10% (user selectable); 50/60 Hz
Environment -10 to 50?C (14 to 122?F); RH 95%
Dimensions 141 x 69 mm (5.6 x 2.7 in.)
Weight 1 kg (2.2 lb.)

Manuals

EC Analog Controller with Input from Probe or Transmitter ? HI8931